Working Principle
Feeding Station
The feeding station is expertly designed to effectively isolate material dust and powder generated during feeding from the human body, operating under negative pressure conditions maintained by the fan.
Dust is meticulously extracted into the filtration system, ensuring separation of gas and material. Filtration methods are employed to adeptly block dust particles within dusty gases.
Dust particles are efficiently captured on the fabric of the filtration bag, purifying the gas. The feeder boasts a simple yet robust structure, offering low investment costs and seamless operation.
The system is renowned for its simplicity and reliability, demanding minimal technical expertise for management and maintenance.
The feeding station is indispensable for unpacking and feeding operations across industries such as pharmaceuticals, food processing, chemicals, plastics, and rubber.
Technical Parameter
Product Configuration
CustomerSite
Product Features
The feeding station ensures that material dust generated is effectively isolated from both the human body and the external environment. Under the fan's negative pressure, dust is efficiently drawn into the filtration system. Upon reaching the set time, it is cleaned by compressed air back blowing into the silo. This equipment is designed for easy operation, observation, maintenance, and cleaning, reducing operational intensity, enhancing the production environment, and ensuring superior product quality. Crafted from durable SS304/316L material, it guarantees longevity and resilience.
Common Troubleshooting
In the event of a malfunction in the dust-free feeding station, please begin by following the procedure outlined below:
Fault phenomenon |
Fault cause |
Troubleshooting |
No backflushing |
The compressed air valve is not open |
Open the compressed air valve |
Pulse valve malfunction |
Check pulse valve |
Filter clogged |
Replacing the filter element |
No electric vibration |
Damaged vibration motor |
Replace the vibration motor |
The vibration motor is not powered on |
Connect the power supply to the vibration motor |
Slow or no fan extraction |
Fan damage |
Replacing the fan |
Filter clogged |
Replacing the filter element |
Should the fault persist after attempting the listed processing methods, contact our sales personnel promptly. We will swiftly diagnose and resolve the issue to your satisfaction.
Application Industry
Dust-Free Feeding Station
Product Application Scope: Food industry, pharmaceutical industry, metallurgy and mining industry, chemical industry.
Materials: Essence, monosodium glutamate, adsorbent, catalyst, graphite, rouge, powder blusher, polyethylene, polypropylene, polyoxyethylene, fertilizer, veterinary medicine, feed, premix, additives, laundry powder, salt, monosodium glutamate, chicken essence, white sugar, seeds.
Customer Reference