Working principle
1. The innovative automatic dust collection system efficiently absorbs and discharges dust, ensuring a pristine working environment by preventing dust generation during the unpacking and feeding process.
2. Versatile device designed to handle 50kg, 25kg, and 15kg bags, catering to various processing requirements with ease.
3. Integrated screening and vibration device streamlines unloading and pipeline transportation, effectively preventing foreign objects from contaminating the material during feeding.
4. With minimal risk of material blockage, optional dust collectors further reduce airborne dust, safeguarding the environment and lowering labor intensity.
5. The storage tank's base is equipped with a customizable active hopper, adaptable to the specific storage box size requirements.
Technical Parameter
Model |
WT300 |
Volume(L) |
300 |
Power(KW)1 |
1.1 |
Compressed air consumption2/Pressure (L/min)/MPa |
50/0.6 |
Discharge interface |
Quick installation 12 inch |
Dust removal fan air outlet |
DN150 |
Weight(Kg) |
300 |
Overall dimension(mm)L×W×H |
1300×1100×2000 |
Product configuration
Customer Site
Product Features
1. Robust yet simple structure ensures an extremely low equipment failure rate.
2. User-friendly operation with minimal training required, promoting quick onboarding.
3. Effectively addresses dust overflow issues, significantly reducing environmental pollution and health hazards.
4. Highly adaptable and customizable to meet specific customer conditions and requirements.
5. Exceptional longevity with low maintenance costs, offering outstanding cost-effectiveness.
Common troubleshooting
When encountering a malfunction in the dust-free feeding station, please follow the initial troubleshooting steps outlined below:
Fault phenomenon |
Fault cause |
Troubleshooting |
No backflushing |
The compressed air valve is not open |
Open the compressed air valve |
Pulse valve malfunction |
Check pulse valve |
Filter clogged |
Replacing the filter element |
No electric vibration |
Damaged vibration motor |
Replace the vibration motor |
The vibration motor is not powered on |
Connect the power supply to the vibration motor |
Slow or no fan extraction |
Fan damage |
Replacing the fan |
Filter clogged |
Replacing the filter element |
If the issue persists after employing the recommended troubleshooting methods, please promptly contact our sales team for swift diagnosis and resolution.
Application Industry
Dust-free feeding station
Wide application scope covering the food industry, pharmaceutical industry, metallurgy and mining industry, and chemical industry.
Handles a diverse range of materials including essence, monosodium glutamate, adsorbents, catalysts, graphite, rouge, powder blusher, polyethylene, polypropylene, polyoxyethylene, fertilizers, veterinary medicine, feed, premixes, additives, laundry powder, salt, monosodium glutamate, chicken essence, white sugar, and seeds.
Customer Reference