Customization: | Available |
---|---|
Capacity(t/h): | 150-300 |
Material: | Stainless Steel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Working principle: The automatic dust collection system by Shijiazhuang Rongxin Science and Technology Co., Ltd effectively absorbs and discharges dust, preventing dust generation during material unpacking and feeding processes, enhancing the working environment.
The device can handle 50kg, 25kg, and 15kg bags to meet various processing requirements. A screening and vibration device aids in unloading and pipeline transportation, preventing foreign objects from entering materials during feeding. Minimized material blockages, optional dust collectors reduce dust dispersion, safeguard the environment, and lessen labor intensity.
The storage tank features an active hopper at the bottom, customizable based on storage box size.
Model | WT100/150 |
Volume(L) | 100/150 |
Power(KW)1 | 0.75/1.1 |
Compressed air consumption2/pressure (L/min)/MPa |
50/0.6 |
Discharge interface | Quick installation 8inch |
Dust removal fan interface | φ100/φ150 |
Weight(Kg) | 150/200 |
Overall dimensions(mm)L×W×H | 900×800×1850 /1000×900×2000 |
Introducing the innovative reverse blowing device from Shijiazhuang Rongxin Science and Technology Co., Ltd. This device efficiently utilizes compressed air for reverse blowing, eliminating the need for separate fans and electrical appliances. Say goodbye to unnecessary power consumption and embrace a more sustainable solution for your air blowing requirements.
Contact us today to learn more about our Small Bag Emptying Feeder Machine!
If there is a malfunction, follow the troubleshooting procedure provided in the manual.
Fault phenomenon | Fault cause | Troubleshooting |
No backflushing | The compressed air valve is not open | Open the compressed air valve |
Pulse valve malfunction | Check pulse valve | |
Filter clogged | Replacing the filter element | |
No electric vibration | Damaged vibration motor | Replace the vibration motor |
The vibration motor is not powered on | Connect the power supply to the vibration motor | |
Slow or no fan extraction | Fan damage | Replacing the fan |
Filter clogged | Replacing the filter element |
Application Industry:
Customer Reference