Working principle
1. Our state-of-the-art automatic dust collection system is meticulously designed to effectively absorb and discharge dust. This innovative feature prevents dust generation during the unpacking and feeding process of materials, significantly enhancing the working environment.
2. Equipped with a versatile device, our system can efficiently handle 50kg, 25kg, and 15kg bags, catering to a wide array of processing requirements.
3. For maximum efficiency, we have incorporated a sophisticated screening and vibration device. This ensures smooth unloading and streamlined pipeline transportation, effectively preventing foreign objects from contaminating the material during the feeding process.
4. Designed with user convenience in mind, our system minimizes material blockage and offers optional dust collectors to further reduce airborne dust, protecting the environment and lessening labor intensity.
5. The bottom of the storage tank is specially equipped with an active hopper. This can be customized according to the size of the storage box, providing flexible solutions tailored to your needs.
Technical Parameter
Model |
RX-WT100 |
RX-WT150 |
RX-WT200 |
RX-WT300 |
Volume(L) |
100 |
150 |
200 |
300 |
Power(KW) |
0.8 |
2 |
2 |
2 |
Noise(dB) |
70 |
80 |
80 |
80 |
0.6MPaCompressed air consumption(L/min) |
5 |
5 |
5 |
5 |
Discharge interface |
DN150 |
DN200 |
DN200 |
DN250 |
Dust removal fan exhaust interface |
φ100 |
φ100 |
φ100 |
φ100 |
Weight(Kg) |
About170 |
About 200 |
About 220 |
About 240 |
Overall dimensions |
800*900*1800 |
900*1000*2200 |
1150*1300*2000 |
850*1100*2600 |
(mm L×W×H) |
Rated parameters of power supply |
380V/50Hz,Three phase five wire power supply |
Short circuit rated current SCCR(KA) |
6 |
Other power source parameters |
The feeding station requires the use of dry and clean compressed air,Pressure≤0.6MPa.Required pressure dew point-20ºC,Dust content 5.0mg/m³(Particle size 5μm),oil content 1.0mg/m³ |
1.Excluding the power requirements of separately selected fans and their associated electrical appliances.
2.Compressed air consumption is only required for the reverse blowing device.
Product configuration
CustomerSite
Characteristics of dust-free feeding station:
1. Boasting a simple structure, our dust-free feeding station ensures safe and convenient operation, along with easy maintenance.
2. Experience truly dust-free operation with our fully enclosed bag feeding and pipeline transportation system.
3. Featuring a no dead corner design, our system is incredibly easy to clean.
4. With an automatic dust removal system, dust flying is a thing of the past, resulting in a significantly improved working environment.
5. Our bag opening stations come in various specifications, designed to meet diverse processing needs.
6. Ideal for industries dealing with powders, including pharmaceuticals, food, chemicals, batteries, and more.
Precautions for use and operation
The dust-free feeding stations manufactured by Shijiazhuang Rongxin Science and Technology Co., Ltd. have undergone rigorous quality control and testing before leaving our factory. To ensure the safe and reliable operation of your dust-free feeding station, please thoroughly read the manual before installation, debugging, and use. This will help you fully understand the operation, maintenance, and safety precautions necessary to keep the machine in optimal working condition.
working condition.
Common troubleshooting
In the event of a malfunction in the dust-free feeding station, please follow these troubleshooting steps first:
Fault phenomenon |
Fault cause |
Troubleshooting |
No backflushing |
The compressed air valve is not open |
Open the compressed air valve |
Pulse valve malfunction |
Check pulse valve |
Filter clogged |
Replacing the filter element |
No electric vibration |
Damaged vibration motor |
Replace the vibration motor |
The vibration motor is not powered on |
Connect the power supply to the vibration motor |
Slow or no fan extraction |
Fan damage |
Replacing the fan |
Filter clogged |
Replacing the filter element |
If the issue persists after following the provided troubleshooting methods, promptly contact our sales personnel. We will swiftly diagnose the cause and provide the necessary solution to resolve the issue.