Automatic bag open cuttingand emptying, Bag unpacking machine
Working Principle
Feeding Station
1,When the small bag powder material needs to be unpacked and transferred to the next process, the only action required is manual unpacking before being fed into the system. The dust generated during this feeding process is efficiently captured by the dust collection fan.
2,The material can be intercepted by a vibrator (safety screen), which effectively blocks large chunks and foreign objects, ensuring that only particles meeting the required specifications are discharged.
Technical Parameter
Model |
WT100 |
WT150 |
Volume(L) |
80 |
120 |
Power(W)1 |
1000 |
1000 |
Compressed air consumption2 /pressure(L/min)/MPa |
50/0.6 |
50/0.6 |
Discharge interface |
Quick installation 6inch |
Quick installation 8inch |
weight(Kg) |
150 |
200 |
Overall dimensions(mm)L×W×H |
900×700×1600 |
1050×800×1850 |
Notice
:
1.The power consumption of the selected fan and its electrical components is not included.
2.Only the compressed air consumption required for the reverse blowing device is considered.
Product Configuration
Customer Site
Product Features
Dust-Free Feeding Station
The equipment features an efficient dust removal function to prevent dust dispersion during unpacking and feeding, minimizing material loss.
A vibrating screen can be installed internally to effectively eliminate any foreign objects during processing.
The equipment integrates intelligent control, providing high automation and ease of operation.
The internal design of the equipment eliminates dead corners, facilitating easy disassembly and cleaning.
The equipment design fully complies with GMP (Good Manufacturing Practices) requirements.
Common Troubleshooting
In case of any malfunction in the dust-free feeding station, please follow the steps below for initial troubleshooting:
Fault phenomenon |
Fault cause |
Troubleshooting |
No backflushing |
The compressed air valve is not open |
Open the compressed air valve |
Pulse valve malfunction |
Check pulse valve |
Filter clogged |
Replacing the filter element |
No electric vibration |
Damaged vibration motor |
Replace the vibration motor |
The vibration motor is not powered on |
Connect the power supply to the vibration motor |
Slow or no fan extraction |
Fan damage |
Replacing the fan |
Filter clogged |
Replacing the filter element |
If the fault persists after following the listed troubleshooting methods, please contact our sales team promptly. We will quickly diagnose and resolve the issue for you.
Application Industry
The dust-free feeding station is adept at handling the unpacking, unloading, and transportation of powdered, granular, and small ton bags. It finds extensive application across various industries, including petrochemicals, raw materials, plastics, carbon black, mining, and food additives, as well as cement production. Featuring a simple structure, low production cost, user-friendly operation, high cost-effectiveness, and an integrated dust collector, it prevents dust from escaping.
Customer Reference