Customization: | Available |
---|---|
Capacity(t/h): | 150-300 |
Feeding Rate Control: | Semi-Automatic |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | RX-WT100 | RX-WT150 | RX-WT200 | RX-WT300 |
Volume(L) | 100 | 150 | 200 | 300 |
Power(KW) | 0.8 | 2 | 2 | 2 |
Noise(dB) | 70 | 80 | 80 | 80 |
0.6MPaCompressed air consumption(L/min) | 5 | 5 | 5 | 5 |
Discharge interface | DN150 | DN200 | DN200 | DN250 |
Dust removal fan exhaust interface | φ100 | φ100 | φ100 | φ100 |
Weight(Kg) | About170 | About 200 | About 220 | About 240 |
Overall dimensions (mm L×W×H) |
800*900*1800 | 900*1000*2200 | 1150*1300*2000 | 850*1100*2600 |
Rated parameters of power supply | 380V/50Hz,Three phase five wire power supply | |||
Short circuit rated current SCCR(KA) | 6 | |||
Other power source parameters | The feeding station requires the use of dry and clean compressed air,Pressure≤0.6MPa.Required pressure dew point-20ºC,Dust content 5.0mg/m³(Particle size 5μm),oil content 1.0mg/m³ |
Fault phenomenon | Fault cause | Troubleshooting |
No backflushing | The compressed air valve is not open | Open the compressed air valve |
Pulse valve malfunction | Check pulse valve | |
Filter clogged | Replacing the filter element | |
No electric vibration | Damaged vibration motor | Replace the vibration motor |
The vibration motor is not powered on | Connect the power supply to the vibration motor | |
Slow or no fan extraction | Fan damage | Replacing the fan |
Filter clogged | Replacing the filter element |